REAR DOOR COOLING
Cooling at the back of the rack.
The HXK Series rear-door heat exchanger replaces the cabinet's rear door and removes heat the moment it leaves the servers — close-coupled cooling for the highest-density racks.
It needs no extra floor space and no structural change to the cabinet; the heat-pipe version uses no compressor, no pump, and keeps water out of the IT room.
Available as heat-pipe or chilled-water, single- or double-door, from 3 to 24 kW per cabinet (with high-density wall versions beyond).
Key capabilities.
Heat-pipe or chilled-water
Single- or double-door (100% redundancy)
No structural change to the cabinet
Why it wins?
Built for high density : 3–24kWpercabinet,rightat the heat source.
Safe & water-free : Phase-changecooling; no condensate, no water in the room.
Proven & reliable : Sealeddoor-shaftconnector; 30,000 units deployed.
100% redundancy : Double-doorversionkeeps cooling if one side stops.
Where you'd use it
Highest-density racks : Heat loads no room AC or in-row can fully absorb.
Modular & micro-module DCs : Cooling at every cabinet in the module.
Cold / hot-aisle data centers : Close-couple the heat before it mixes.
Space-constrained rooms : No extra floor area; mounts on the cabinet.
Features & technology
Phase-change heat-pipe — no compressor, no pump; water stays out of the room
Double-door redundancy — 100% — cooling continues if one side stops.
Proven connector — 145 bar, 100,000 cycles leak-free; 4 yrs zero failures.
Fully sensible cooling — no condensate to manage.
No structural change — hangs on the cabinet's rear tie-points.
No structural change — hangs on the cabinet's rear tie-points.
Specifications
HEAT-PIPE REAR-DOOR

CHILLED-WATER REAR DOOR

Common — rear-door 48 V DC, control box 380 V 3N 50 Hz · heat-pipe (R410A) or chilled-water · door opens ≥110° · 304/316 stainless hinges · high-density wall versions 25–75 kW available.
Questions, answered
How is it different from room AC? — It cools at the back of the rack, taking heat the instant it leaves the servers ideal for densities room AC can't handle.
What about redundancy?— The double-door version gives 100% redundancy cooling continues if one side stops.
Does water enter the IT room? — No, the heat-pipe version uses phase-change refrigerant; no compressor, no pump, no condensate.
Heat-pipe or chilled-water? —Heat-pipe for the simplest, water-free install; chilled-water with a CW plant. 3–24 kW per cabinet.